226 Panel_140

Rockwool
Category: Panel/Roll
Type: Thermo-acoustic insulation
Application area: External wall,

Uncoated rock wool rigid panel in medium density, for thermal and acoustic insulation of perimeter walls.

Main Materials

rock wool

Dimensions

Length (m) 1.200
Width (m) 0.600
Depth (m) 0.140

Standard Reference

EuroClass Fire A1
Reference Service Life (years) 30

Thermal Transmittance (W/(m2K)): 0.250

Layer: rock wool

Vapour resistance (μ) 1.0
Conductivity of materials (W/(mK)) 0.035
Thermal resistance of materials (m2K)/W 4.000
Thickness of materials (m) 0.140
Density of materials (kg/m3) 60
Specific Heat of materials J/(kgK) 1030
Layer EuroClass Fire A1
Functional Unit [m2]
Global Warming [kg CO2, eq] 9.272
Acidification [kg SO2, eq] 0.064296
Eutrophication [kg PO4--- eq] 0.0059204
Ozone Layer Depletion [kg CFC-11 eq] 1.0868E-8
Photochemical Oxidation [kg NMVOC]
Abiotic Depletion, elements [kg Sb eq] 3.1616E-6
Abiotic Depletion, fossil fuels [MJ] 103.36

An LCA has been performed by Stress and the dataset has been modelled with the help of Simapro 9.1 and Ecoinvent v3.6

Function Unit [€/m2]
Selling price 16.11
Construction/Installation Cost 3.22
Yearly maintenance costs 0.00