226 Panel_80

Rockwool
Category: Panel/Roll
Type: Thermo-acoustic insulation
Application area: External wall,

Uncoated rock wool rigid panel in medium density, for thermal and acoustic insulation of perimeter walls.

Main Materials

rock wool

Dimensions

Length (m) 1.200
Width (m) 0.600
Depth (m) 0.080

Standard Reference

EuroClass Fire A1
Reference Service Life (years) 30

Thermal Transmittance (W/(m2K)): 0.444

Layer: rock wool

Vapour resistance (μ) 1.0
Conductivity of materials (W/(mK)) 0.035
Thermal resistance of materials (m2K)/W 2.250
Thickness of materials (m) 0.080
Density of materials (kg/m3) 60
Specific Heat of materials J/(kgK) 1030
Layer EuroClass Fire A1
Functional Unit [m2]
Global Warming [kg CO2, eq] 5.2155
Acidification [kg SO2, eq] 0.0361665
Eutrophication [kg PO4--- eq] 0.003330225
Ozone Layer Depletion [kg CFC-11 eq] 6.11325E-9
Photochemical Oxidation [kg NMVOC]
Abiotic Depletion, elements [kg Sb eq] 1.7784E-6
Abiotic Depletion, fossil fuels [MJ] 58.14

An LCA has been performed by Stress and the dataset has been modelled with the help of Simapro 9.1 and Ecoinvent v3.6

Function Unit [€/m2]
Selling price 9.21
Construction/Installation Cost 1.84
Yearly maintenance costs 0.00