Air-fix_120

Sitav
Category: Ventilated facade
Type: Thermo-acoustic insulation
Application area: External wall,

The Air-fix system allows to create a ventilated facade with metal insulated panels while maintaining mechanical characteristics of adequate resistance to stresses. Air-fix, (product name inspired by its properties: dry fixing and ventilation) without through holes, can connect porcelain stoneware, wood or metal and polycarbonate coatings. No screws, bolts, blind rivets, self-drilling screws with interposed synthetic rubber gaskets or sheaths are required.

Main Materials

porcelain stoneware

Dimensions

Length (m) -
Width (m) -
Depth (m) -

Standard Reference

EuroClass Fire
Reference Service Life (years) 40

Thermal Transmittance (W/(m2K)): 0.180

Layer: porcelain stoneware

Vapour resistance (μ)
Conductivity of materials (W/(mK))
Thermal resistance of materials (m2K)/W
Thickness of materials (m)
Density of materials (kg/m3)
Specific Heat of materials J/(kgK)
Layer EuroClass Fire A1

Layer: air

Vapour resistance (μ)
Conductivity of materials (W/(mK))
Thermal resistance of materials (m2K)/W
Thickness of materials (m)
Density of materials (kg/m3)
Specific Heat of materials J/(kgK)
Layer EuroClass Fire A1

Layer: EV1M panel

Vapour resistance (μ)
Conductivity of materials (W/(mK)) 0.020
Thermal resistance of materials (m2K)/W 5.550
Thickness of materials (m) 0.120
Density of materials (kg/m3) 39
Specific Heat of materials J/(kgK)
Layer EuroClass Fire A1
Functional Unit [m2]
Global Warming [kg CO2, eq] 9,15E+01
Acidification [kg SO2, eq] 4,93E-01
Eutrophication [kg PO4--- eq] 1,81E-01
Ozone Layer Depletion [kg CFC-11 eq] 8,90E-06
Photochemical Oxidation [kg NMVOC] 3,74E-01
Abiotic Depletion, elements [kg Sb eq] 2,49E-02
Abiotic Depletion, fossil fuels [MJ] 1,22E+03

An LCA has been performed by Stress and the dataset has been modelled with the help of Simapro 9.1 and Ecoinvent v3.6

Function Unit [-]
Selling price
Construction/Installation Cost
Yearly maintenance costs